Therapeutic Ultrasound CSL-5

 42,000

Powerful Professional & Affordable Ultrasound
This is an advance therapeutic Ultrasonic Therapy device produce sound waves of 1 MHz frequency used to stimulating the tissue beneath the skin’s surfaces, the high frequency massage (stimulation effect) penetrates up to 5″ below the skin surface and the effect like micro massage affects very small molecules and membrane cells of tissue in the body and actually causes them to move one place to another and vibrate them at their own place and get them heat up.

In Stock

-
+
Add to Wishlist
Add to Wishlist

Description

Therapeutic Ultrasound CSL-5
Powerful Professional & Affordable Ultrasound
This is an advance therapeutic Ultrasonic Therapy device produce sound waves that are used to stimulating the tissue beneath the skin’s surfaces, the high frequency massage (stimulation effect) penetrates up to 5″ below the skin surface and the effect like micro massage affects very small molecules and membrane cells of tissue in the body and actually causes them to move one place to another and vibrate them at their own place and get them heat up.
The continuous high frequency penetration into the cells and molecules results the thermal damages therefore the method of intermitted cycle penetration energy in the better way relief the pain. It is way of frequency modulation in the pattern of high frequency or low frequency. It comes in penetration ON and penetration OFF.
The unit is absolutely compact lightweight device, designed with micro-controller based electronic solid state technique and assembled in powder coated metal chassis, very variable and convenient for clinical use, comfortable for visiting consultants, long running use and personal as well as professional purpose.
Insure, before to use this high frequency generator for the treatment to the patient, the condition and disease for which the treatment is being after to the particular area of the patient should be properly diagnosed by an expert therapist, the treatment may be given.
ADVANCE FEATURES:
The unit is designed with latest technology, which comprises the following features:
DISPLAY
All modes treatment timer and intensity displays are provided at the front panel, including LED indicator for easy visibility of friendly use for selected operational mode. The mains ON/OFF switch and transducer socket are provided at front.
USER FRIENDLY OPERATION
The modes of operation, which are provided at front panel, can be selected by the Switch and the mode of use will be identified by LCD display and also time and intensity level.
MONO FREQUENCY OPERATION
This unit has a 1 MHz frequency generator with transducer head for deep penetration into the tissue and healing the lesion muscle approx 5″ area from the surface where applied the high frequency energy and the intensity can be applied as the required area and treated by approx 2.5″ diameter transducer lead.
CONTINUOUS AND PULSE MODE APPLICATION
A continuous transmission of frequency and carried power energy produced into the tissue, efficiently absorbed by portion are connected heat, accelerate the heating and extensively increase the collagen, thus the stretching in stiffness is easier. A thermal effect (Pulse Mode) energy generation is adopted to avoid the tissue from the complications due to the thermal effects or ultrasound producing into the tissue at all. Cavitations behavior can lead to the formation of highly reactive free radicals although free radicals are produced by cells naturally which are removed by free radicals scavengers, excess production of natural free radicals scavenger system could however be damaging and decrease of intensity cause cavitations use of continuous some time damage the tissue cells due to the excessive energy constantly produced into the tissue and use of pulse wave forms of ultrasound increase the collagen synthesis 30% against the 20% of continuous wave form with the same power ratio.
Biological effect related cavitations and micro mass age cells degramulations change on cells membranes functions, increase the level of intracellular calcium, broblast activity stimulation resulting increased protein synthesis, neoangiogensis collagens elastic tension with those effects more pronounced with pulse ultrasound.
INTENSITY
The power energy produced, unit of power intensity is w/cm2 to 3.5w/cm2 and the diameter area of the transducer is playing significant role for the intensity transmission to the area to be applied for treatment similarly when applied in pulse mode, different pulse modulations are provided and the power intensity reduced in similar ratio.
AUDIO INDICATION
As the treatment time gets over all set parameters becomes Reset ‘0’ condition for further implementations and an audio indication start giving by 33er.
OPERATING INSTRUCTIONS
This unit is designed with the latest technology with safety of patient and the user both even it is recommended by the producer (company) before to be used always check the proper functionality of the unit then apply to the patient for treatment.
The main line Cord should be properly attached to socket provided in the back side of the unit through a proper voltage stabilizer.
And the transducer head lying on the hanger by right side of the unit should be properly attached to the socket.
A digital timer can be selected for desired treatment and after completion of treatment time an audio alarm switched ON and controller cuts off the delivery of power output.
The mode of application can be selected thereafter either in continuous or pulsed mode delivery of power along with different pulse modulations per second.
Pulse mode selection is 1 pulse per second to 9 pulse per second available which can be selected as the requirement of the treatment recommended.
Power level 0.1w/cm to maximum 3.5w/cm depending upon the area to be treated and the condition of the disease.
A good quality conductive jelly should be applied for treatment on the area where the treatment has to be given for better performance on the unit.
Press START/STOP (S/S) switch after selecting all the parameters.
After completion of treatment as selected for prescribed time and dose, the transducer head should be properly cleaned and put on the hanger lying on one side of the unit.
Always the machine should be switch OFF from the mains after completion of treatment time.
STANDARD ACCESSORIES
Ultrasonic Applicator 1 PC
Main Cord 1 PC
Unit Cover 1 PC
FRONT PANEL
Knob For Increasing/decreasing pulse duration.
Knob For Increasing/decreasing Intensity
Display For Power Output
Switch For Selecting Pulse / Cont.
Output for Handle